 Interlock Switches
Guard Locking Switches
Spartan Specifications
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems CE marked for all applicable directives, cULus and TUV Nord 2 N.C. or 3 N.C. direct opening action AC 15 AC (Ue) 500V 250V 100V (le) 1A 2A 5A DC 250V/0.5A 24V/2A
Category
Approvals Safety Contact Utilization Cat.
Description
The Spartan is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and ensures that it remains isolated while the guard is open. It is available in two contact configurations: two safety (N.C.) contacts and one auxiliary (N.O.) contact or three safety (N.C.) contacts. The Spartan head has two entry slots and it can be rotated to provide four actuator entry points. A blanking plug is provided to seal the unused slot. The guard may only be opened when a signal is applied to the Spartan's internal solenoid which releases the lock mechanism. Therefore the Spartan is ideal for machines which do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard. The locking mechanism withstands forces up to of 1200N (270lbs.) and an LED provides visual indication of switch status. A catch kit with actuator alignment is also supplied to relieve stress on the locking solenoid and to protect the unit from actuator damage due to poor guard alignment. Manual release points with security screws or special key allow the locked Spartan to be released in the event of total power failure on a machine.
Maximum Switched Current/ 500V/500VA Volt/Load Thermal Current (lth) Min Current Safety Contact Gap Rtd. Insulation Voltage Rtd. Impulse withstand Volt Auxiliary Contacts Pollution Degree Max Actuation Speed Max Actuation Frequency Case Material Actuator Material Protection Conduit Entry Operating Temperature Fixing Mounting Mechanical Life Electrical Life Weight Colour Max Holding Force Min Operating Radius LED Indication Power Supply Solenoid Power 10A 5V 5mA DC >2mm 500V 2500V 1 N.O. 3 160mm/second (6.3 in/sec) 1 cycle/second UL Approved glass filled polyester Stainless steel IP 67 1 x M20 or quick disconnect style -20C to 60C (-4F to +140F) 2 x M5 Any position 1,000,000 operations 1,000,000 operations 260g (0.57 lb) Red 1200N (270lbs) 175mm (6.9in) Solenoid monitor LED 24V AC/DC, 110V AC, 230V AC (solenoid) Typically 7W 100% ED
Features
* * * * * Power to release Lid mounted status indication High locking force--1200N (270lbs.) 2 N.C. & 1 N.O. or 3 N.C. Rotatable head: 4 possible key entry slots
Conductive pollution occurs, or dry, non conductive pollution occurs which becomes conductive due to condensation.
Typical Applications
Note: Lift-off guards require good alignment when using tongue actuated interlock switches. IMPORTANT: It must not be possible to lift the guard without actuating the interlock. An interlock on either side may be required.
3-24
Interlock Switches
Guard Locking Switches
Spartan Product Selection
Contacts Actuator Solenoid Voltage 24 V AC/DC Safety 2 N.C. 3 N.C. 2 N.C. Standard 110 V AC/DC 3 N.C. 2 N.C. 3 N.C. Aux. 1 N.O. -- 1 N.O. -1 N.O. -- M20 Conduit 440G-S36001 440G-S36007 440G-S36003 440G-S36009 440G-S36005 440G-S36011 Catalogue Number M20 Conduit/ 1/2in Adaptor 440G-S36044 440G-S36047 440G-S36045 440G-S36048 440G-S36046 440G-S36049 Quick Disconnect 440G-S36058 440G-S36059 440G-S36060 440G-S36061 440G-S36062 440G-S36063
230V AC/DC
Mating cable 2m (6.5ft). See page 15-13 for details and additional lengths.
889M-F12X9AE-2
Accessories
Description For Dimensions refer to page Catalogue Number
Replacement Actuator with Catch Retainer and Guide
14-4
440G-A36050
Emergency Override
14-4
440G-A36026
3-25
Interlock Switches
Guard Locking Switches
Spartan Approximate Dimensions--mm (inches)
Dimensions are not intended to be used for installation purposes.
14.5 (0.57) 35 (1.38) 12 (0.47) 120 (4.72) Conduit Entry (M20) 31 (1.22) 37 (1.46) 8 (0.31) 3 N.C. Safety Circuit 3
40 (1.57) 9 (0.35) Emergency Release Points
7 (0.28)
5 (0.2)
58 (2.28) 52 (2.05) 40 (1.57)
Key
O5.5 (0.22)
8 (0.3)
34.5 (1.36)
Typical Wiring Diagrams
2 N.C. + 1 N.O. Auxiliary Circuit Safety Circuit 2 Safety Circuit 1 AC/DC Solenoid Power
22
34
33
21
20.5 (0.81)
5.5 (0.22)
Safety Circuit 2 Safety Circuit 1
14 (0.55)
22 32
31
21
12 A2
11 A1
AC/DC Solenoid Power
12 A2
11 A1
Solenoid AC/DC 100% ED.
Solenoid AC/DC 100% ED.
2 N.C. + 1 N.O. Connector Pinout 1 3 4 6 7 8 9 10 12 Terminal A1 A2 11 12 21 22 33 34 Contact Solenoid Power N.C. N.C. N.O. Ground
2 N.C. + 1 N.O. 12 11/12 21/22 33/34 6 0mm 12 11/12 21/22 33/34
3 N.C. Terminal A1 A2 11 12 21 22 31 32 Contact Solenoid Power N.C. N.C. N.C.
8 7 6 5 12
9 11
1 10 2 3 4
Contact Action
Contact Open Contact Closed Actuator withdrawal distance from full insertion
3 N.C. 6 0mm
2.5
2.5
3-26
Interlock Switches
Guard Locking Switches
Spartan Application Details
4 possible actuator entry positions
1 2
Locking Force = 1200N
3-27


▲Up To Search▲   

 
Price & Availability of 440G-S36007

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X